Connecting Industrial Light

Connecting Industrial Light

To connect an industrial light to a PV-50C camera, you must connect pin number 4 of the camera’s pin assignment, labeled OUT1 (Camera Line 2), to the +24V power pin on the light.

 

Screenshot 2025-02-18 at 16.57.02.png
Pin assignment from the power M12 connector on PV-50C camera

Setting up the software through camera settings

To set up the light, you have to go to the camera settings in the camera tab.

Screenshot 2025-02-18 at 16.42.20-20250218-160334.png
PEKAT VISION Software interface - camera tab

Select level of settings - expert or guru.

 

Then select DIGITAL IO CONTROL. Line selector has be set to Line2. Camera line 2 is outputting to OUT1 on the M12 connector pin assignment. You have to set Line Mode to Output. Then select Line source based on your preference.

Line source options:

  • ExposureActive - during the image acquisition (camera exposure), the light is ON.

  • TriggerReady - Light is ON when the trigger is received.

  • UserOutput1 - Output is set based on the User Preference under “User Output Value All - min 0 - max 7”.